Description

LFT2000 pressure transmitter is widely used in the measurement of fluid medium pressure in test systems such as fireprotection,water treatment,water supply systems,air compressors,pneumatic devices,and factory automation.Adopt ceramic sensitive diaphragm with high overload capacity.It has excellent anti-corrosion and anti-wearperformance,adopts ASIC technology,MEMS technology,and digital compensation And it has the characteristics ofsmallsize and low price,can be applied in various complex environment.

Specification

Measurement Range-100kPa~0.3MPa.…6MPa
Overload Pressure1.5 times the rated pressure
Burst Pressure2 times the rated pressure
Accuracy①±0.5%F.S、±1.0%F.S
Stability<0.5%F.S/year
Working Temp-20~85℃
Storage Temp-40~100℃
Measured MediumGas or liquid compatible with 1Cr18Ni9Ti,304 stainless steel,Fluorine rubber or Nitrile rubber
Electrical Properties2-wired3-wired
Output Signal4~20mA0.5~4.5V0~5V0~10V
Power Supply8~36VDC4.75~5.25VDC8~36VDC12~36VDC
Electrical ConnectionsPackard,DIN43650C(small Hirschmann),DIN43650A(big Hirschmann),M12 waterproof outlet,
M12 aviation connector,GX12 aviation connector (three-core/four-core)
Enclosure ProtectionIP54(GX12 aviation connector,Packard)、IP65(DIN43650A,DIN43650C,M12 waterproofoutlet,
M12 four-core aviation connector)
Pressure connectionG1/4、NPT1/4、R1/4、BPS1/4、G1/2、7/16-20UNF、M20*1.5、M10*1、M14*1.5 etc
Pressure FormGauge Pressure G
CertificationRoHS、EU electrical safety standard CE

①Measured at 25℃,including the comprehensive accuracy of linearity,repeatability and hysteresis

Product Selection

Code and descriptionRemark
LFT2000Model
Range-100kPa~0.3MPa..6MPaMeasurement
Range
K  K=kPaPP=psi
Measurementt
Unit
B  B=BarMM=MPa




A4A4=4~20mA(2-wired)Output Mode
V05V05=0.5~4.5V(3-wired)
VOVO=0~5V(3-wired)
V10V10=0~10V(3-wired)
0.5 0.5=0.5%F.SAccuracy
1.0 1.0=1.0%F.S
P  P=Packard(Packard)Electrical
Connection
D  D=DIN43650C(Small Hirschmann)
D1  D1=DIN43650A(Big Hirschmann)
M  M=M12(M12 waterproof outlet)
C3  C3=GX12 Three core aviation connector
C4  C4=GX12 Four core aviation connector
H  H=M12 Four core aviation connector
GG=G1/4G2G2=G1/2Pressure
Connection
NN=NPT1/4M20M20=M20*1.5
RR=R1/4UU=7/16-20UNFExtemal thread
BB=BSP1/4
1.0 1.0=1mCable Length
2.0 2.0=2m
3.0 3.0=3m
LFT2000      0-16      B      A4     1.0     P     G      1.0                            Selection Example