Contact Form

LFT2100 General-Type Pressure Transmitter

PRODUCT FEATURES

  • Unique waterproof and breathable structure
  • Excellent corrosion and anti-wear resistance
  • Adopt ceramic sensitive diaphragm with high overload capacity
  • With a variety of threaded connection and electrical connections
  • Small size,can be applied in various complex environment
Description
Specification
Product Selection
FAQs
Request A Quote

Description

LFT2100 is widely used in fire fighting,water treatment,water supply systems,air compressors,pneumatic devices,factory automation and other test systems for the measurement of fluid medium pressure.Unique waterproof andbreathable structure to prevent internal and external air pressure inconsistency resulting in precision deviation.High overload capacity ceramic sensitive diaphragm with excellent corrosion and wear resistance.ASICtechnology,MEMS technology,digital compensation technology,high precision,low temperature drift.Theproduct also has the characteristics of small size,high protection level and strong anti-interference ability,and canbe applied to various complex environments.

Specification

Measurement Range-0.1MPa~0.….3MPa,0~0.1MPa..6MPa
Overload Pressure1.5 times the rated pressure
Burst Pressure2 times the rated pressure
Accuracyb note10.5%F.S(range>0.3MPa)、1.0%F.S
Stability<0.5%F.S/year
Working Temp.-20~85℃
Storage Temp.-40~100℃
MediumGas or liquid compatible with Alumina ceramics,304 stainless steel,fluororubbers or nitrile
butadiene rubber
Electrical Properties2-wired3-wired
Output Signal4~20mA0.5~4.5V0~5V0~10V
Power Supply10~36VDC4.75~5.25VDC10~30VDC12~30VDC
Electrical ConnectionPackard、DIN43650C(Small Hirschmann),Direct outlet,4 core M12 Aviation connector
Enclosure ProtectionIP65
Pressure ConnectionG1/4、NPT1/4、R1/4、BPS1/4、G1/2、7/16-20UNF、M20*1.5、M10*1、M14*1.5 etc
Pressure FormGauge pressure G
CertificationRoHS、CE

Note 1:Measurement at 25℃,includes a combined accuracy of linearity,repeatability and hysteresis.

Product Selection

Code and descriptionRemark
LFT2100Model
Range-0.1MPa~0.…3MPa,0~0.1MPa.…6MPaMeasurement range
A  A4=4~20mA(2-wired)Output type
V05   V05=0.5~4.5V(3-wired)
V  VO=0~5V(3-wired)
V10   V10=0~10V(3-wired)
KK=kPaP P=psi
Measurement
unit
MM=MPaB B=Bar
0.5  0.5=0.5%F.SAccuracy
1.0  1.0=1.0%F.S
PP=Packard(Packard)Electrical
Connection
DD=DIN43650C(Small Hirschmann)
ZZ=Direct outlet
C4C4=4 core M12 aviation connector
G G=G1/4G2G2=G1/2Pressure
Connection
N N=NPT1/4M20M=M20*1.5
R R=R1/4BB=BSP1/4
1.0 1.0=1mCable Length
2.0 2.0=2m
LFT2100   0-1    A4      M     1.0     P     G     1.0Example

For example:LFT21000-1A4M 1.0PG 1.0(LFT2100 pressure transmitter,range 0-1MPa,output 4-20mA,accuracy1.0%,packard connection,pressure port G1/4,outlet length 1m)

FAQs

REQUEST A QUOTE