Contact Form

LFT3100 Temperature and Pressure Integrated Transmitter

PRODUCT FEATURES

  • Adopt oil-filled diffusion silicon core with high precision and high overload capacity
  • Temperature and pressure dual output,compact structure,saving installation space
  • Support Modbus-485 communication protocol(intelligent type)
  • The temperature-sensitive element and the pressure-sensitive element are packaged as a whole,which is closer to the medium temperature
Description
Specification
Product Selection
FAQs
Request A Quote

Description

LFT3100 temperature and pressure integrated transmitter adopts advanced piezoresistive pressure sensor and PT-100temperature sensor,which is converted into a standard output signal through a special signal conditioning circuit.It has theadvantages of advanced temperature digital compensation,wide operating temperature range and full output signals.It issuitable for the monitoring of pressure and temperature in crude food and water treatment systems.

Specification

Measurement Range0~10kPa….70MPa
Temperature Range-20~100℃(PT-100)
Overload Pressure1.5 times of the rated pressure
AccuracyPressure:±0.5%F.S Temperature:±2%F.S

Stability

<0.5%F.S/year

Working Temp
-20~85℃
Storage Temp-40~100℃
Measured MediumGas or Liquid Compatible with 304 or316L Stainless Steel,Fluorine rubber or Nitrile rubber
Electrical Perfomnance2-wired3-wired4-wired
Output Signal4~20mA0.5~4.5VRS-485
Power Supply10~30VDC4.75~5.25VDC10~30VDC
Electrical ConnectionDIN43650A(Big hirschmann),M12waterproof outlet,GX12 aviation connectorfthree core/
four core),M12 four core aviation connector
Enclosure ProtectionIP54(GX12 aviation connector)、IP65(DIN43650A,M12 waterproof outlet,M12 four-core
aviation connector)
Pressure Connection
G1/4、M12*1、M10*1、NPT1/4、G1/2、M20*1.5etc.
Pressure Form
Gauge pressure G/Absolute pressure A
CertificationRoHS、EU electrical safety standard CE

Product Selection

Code and descriptionRemark
LFT3100 Model
  Pressure Range  0~10kPa…70MPaRange
  KK=kPaP P=psiMeasurement
Unit
MM=MPaB B=Bar
 TR-20~100℃Temperature
 22=2%F.S(Temperature Accuracy)Accuracy
  A4A4=4~20mA(2-wired)Output Mode
 V05V05=0.5~4.5V(3-wired)
  RSRS=RS-485(4-wired)
 0.50.5=0.5%F.SAccuracy Grade
 D1D1=DIN43650A(Big Hirschmann)Electrical
Connection
MM=M12(M12 waterproof cable outlet)
C3C3=GX12 three core aviation connector
C4C4=GX12 four core aviation connector
HH=M12 four core aviation connector
 GG=G1/4NN=NPT1/4Pressure
Connection
G2G2=G1/2M20M20=M20*1.5
M10M1=M10*1M3M12=M12*1
   11.0=1mCable Length
22.0=2m
33.0=3m
   
LFT3100     0-60       M    0-100℃    2      A4    0.5   M    G    1.0Selection Example

FAQs

REQUEST A QUOTE

REQUEST A QUOTE